When do you need an EICR?

Last updated 6 October 2026

The short answer

If you let a home in England on a tenancy covered by the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020, the fixed wiring must be inspected and tested by a qualified and competent person at least every five years. The result is an Electrical Installation Condition Report (EICR). Existing tenants get a copy within 28 days of the inspection, new tenants before they move in, and the council within 7 days if it asks for one. Owner-occupiers have no legal duty, but Electrical Safety First recommends an inspection at least every ten years, and whenever you buy a home.

Source: Electrical Safety First (opens in a new tab) / GOV.UK (opens in a new tab)

Who the five-year rule applies to

The regulations cover most private tenancies in England, including houses in multiple occupation. They applied to new tenancies from 1 July 2020 and to existing tenancies from 1 April 2021, so every covered let should now have a report less than five years old.

Some lets are excluded, including lodgers who share the home with the landlord, long leases of seven years or more and social housing. The GOV.UK guidance has the full list, and it is worth checking before deciding a property is out of scope.

What the codes on the report mean

The inspector records each problem with a code. Any C1, C2 or FI makes the report unsatisfactory, and the work must be done within 28 days, or sooner if the report says so. The landlord then gives written confirmation from the electrician to the tenants and to the council within 28 days of the work being finished.

  • C1 — danger present. Risk of injury, and it needs putting right immediately.
  • C2 — potentially dangerous. Urgent remedial work is required.
  • C3 — improvement recommended. Not a legal requirement to fix under the regulations.
  • FI — further investigation required without delay.

When to get one sooner

Five years is the longest gap allowed, not a target. If the inspector writes a shorter interval on the report, that interval is the one that applies. A new report is also sensible after a flood or fire, after major alterations, and before letting a property for the first time.

A change of tenant does not by itself trigger a new inspection: the existing report carries over as long as it is still in date, and the new tenant is given a copy before moving in.

What happens if a landlord does not comply

The council enforces the regulations. It can require remedial work, arrange the work itself and recover the cost, and impose a financial penalty of up to £30,000.

Common questions

Can any electrician carry out an EICR?
The regulations require a qualified and competent person. Checking that the electrician is registered with a competent person scheme, such as NICEIC or NAPIT, is the simplest way for a landlord to be confident of that.
Does the EICR cover appliances like kettles and fridges?
No. The 2020 regulations cover the fixed installation: wiring, sockets, light fittings and the consumer unit. Electrical Safety First recommends that landlords also check any appliances they supply.
Do I need a new EICR when tenants change?
Not if the current report is still within its five years, or within any shorter interval the inspector set. Give the new tenants a copy before they move in.

Source: Electrical Safety First (opens in a new tab) / GOV.UK (opens in a new tab)

General information for England, not legal advice. Check the source before relying on it for a particular property.